Univer AE-3000 is providing stable air bubble to all type concrete. It is meet to ASTM C 260 and improves the properties of fresh concrete. Thus it gives concrete better cohesion and workability, reduced segregation and bleeding which often occur when utilizing low quality aggregates and harsh mixes.
  • Increases resistance to damage from freezing and thawing
  • Low slump concrete
  • Flowable concrete
  • High temperature concrete
  • Concrete with extended working times
  • Lightweight and prestressed concrete
  • Increasing the entrained air content of concrete with air entraining
  • Increasing flow and workability
  • Micro air bubble increases
  • Reduce segregation and bleeding.

DIRECTIONS FOR USE

Univer AE-3000 should be dispensed into the fresh concrete or with the final quantity of mixing water. It should not come into contact with dry cement or other admixtures until they are mixed in the concrete batch. Univer AE-3000 should be ideally dispensed with automatic equipment, thus ensuring uniformity of admixture used throughout the job.

DOSAGE

There is no standard dosage rate due to differences in concrete making materials and conditions. However, normal dosage rate is between 0.01%~0.06% against binder. In case of special job conditions, we recommend our specialists to be contacted.
Overuse may result in lower than expected strengths

PACKAGING AND STORAGE

Univer AE-3000 is supplied in 5, 10,25 and 205 liters drums or bulk delivery. Univer AE-3000 should be stored under shade. The shelf life Univer AE-3000 is 12 months in its unopened drums and tanks. Once opened, we recommend that the balance be consumed within 3 months. Stir the content prior to use.


SAFETY OF HANDLING

Univer AE-3000 does not contain any hazardous chemicals and non toxic. But it is recommended that safety glows are used in handling the product, in case of skin contact, wash with soap and warm water, if consumed accidentally, immediately consult healthcare provider.

TECHNICAL SERVICE

The company provides good servicing from a team of dedicated specialists in the field. When used in accordance with its current published directions, the product will perform as described in this catalogue. Millennium Concrete Technologies will not be responsible for difficulties caused by other materials, conditions or inferior workmanship and quality control. We reserve the right to determine the true cause of any difficulty by accepted test methods.